Sunrise Auto Components — Manesar Plant 2

Compressor house B · 5 compressors · 2 dryers · 5 m³ receiver
Pressure in band 3 active alerts All gateways online

4 of 5 compressors running. C3 discharge temperature is above the warning limit.

Live · updated a moment ago

Compressor house B, right now

LoadedUnloadedStandbyWarningTripped
Receiver5 m³ 6.9 bar Dryer D1Running · dew point 3.1 °C Dryer D2Standby Plant header 6.8 bar Band 6.5 – 7.2
    Header pressure
    6.8bar
    6.0Band 6.5 – 7.28.0
    Running4 of 5 Loaded3 Total power268 kW Energy today4,910 kWh Dew point3.1 °C Ambient34 °C Starts last hour11

    Active alerts

      Energy today

      4,910 kWh≈ ₹41,300 · yesterday 7,010 kWh

        Next service

          Alerts

          Limits are set under Settings

          Active

          3 active · 1 acknowledged

            Last 7 days

              Compressors

              Values read from each controller

              Energy

              kWh from the controllers · ₹ at your tariff of ₹8.40/kWh
              4,910 kWhtoday so far · ≈ ₹41,300
              Shift A · 06–14
              3,260 kWh
              ₹27,400
              Shift B · 14–22
              1,650 kWh
              running
              Shift C · 22–06
              Loaded hours today (fleet)31.2 h Unloaded hours today (fleet)8.6 h This month so far56,400 kWh · ₹4.74 lakh Same days last month53,100 kWh

              By machine, today

                Last 7 days

                kWh per day · Sunday was a holiday
                Wed
                Thu
                Fri
                Sat
                Sun
                Mon
                Tue

                Trends

                Service

                Counted down from each controller's running hours

                  Data connection

                  So "no data" is never mistaken for "machine off"
                  Gateway 1 · C1, C2, C4Modbus RTU · 4G signal good · last seen 6 s ago
                  Gateway 2 · C3, C5, dryersModbus TCP · 4G signal good · last seen 9 s ago
                  Controller links7 of 7 responding
                  Data gaps, last 30 daysNone

                  Gateways store 24 hours of data if the network drops and back-fill automatically. An alert is raised if a gateway is silent for more than 10 minutes.

                  Reports

                  Sent automatically to the people set under Settings
                  • Daily report · 8 Sep
                    Running hours, alerts, energy per shift, service due
                  • Weekly summary · 1–7 Sep
                    Hours, loaded/unloaded split, kWh by machine, alert count
                  • Monthly energy report · August
                    kWh and ₹ by machine and shift, month-on-month
                  • Alarm history · last 90 days
                    Every warning and trip with time and acknowledgement

                  Settings

                  Alert limits apply to this plant

                  Alert limits

                  Notifications and plant